DOCUMENT ID: 20029
SYNOPSIS: A1000/A3x00/A3500FC Software/Firmware Configuration Matrix - v1.47
DETAIL DESCRIPTION: S U N   E A R L Y   N O T I F I E R

Date: October 28, 2002
 
 
 

Minimum and Recommended OpenBootProm/FlashProm levels for server w/ A1000, A3000, or A3500
Server Type OBP Patch Minimum
OBP Level
Latest
OBP Level
Ultra Enterprise 5/10* 106121-18 3.11.9 3.31.0
Ultra Enterprise 30* 105930-06 3.11.2 3.27.0
Ultra Enterprise 60/220R 106455-11 3.11.26 3.31.0
Ultra Enterprise 250 106503-07 3.7.7 3.26.0
Ultra Enterprise 80/420R 109082-05 3.23.0 3.31.0
Ultra Enterprise 450 106122-10 3.7.107 3.26.0
Ultra Enterprise 3X00/4X00/5X00/6X00 103346-29 3.2.16 3.2.29
Ultra Enterprise 10000 110316-04 3.2.3 3.4
SunFire 880 112186-06 4.2.0 4.6.7
SunFire V480* 113034-03 4.5 4.6.8
SunFire 280R & SunBlade 1000* 111292-10 4.0.31 4.6.7
SunBlade 100* 111179-05 4.0.31 4.6.5
SunFire 3800/4800/4810/6800 112494-06 5.11.4 5.13.3
Sun Fire 12K/15K** - FCS FCS

* indicates A1000 ONLY support for Ultra 5/10/30, Sun Fire V480 & SunBlade 100/1000

** indicates A3500FC ONLY support for Sun Fire 12K/15K

The following table shows the Solaris operating system release and the most recent levels of software and firmware for the StorEdge Array A1000/A3x00(a). The patches are ones that have been tested explicitly with RM 6, even though later versions may have also been tested by other groups.

Minimum Recommended Levels of Software/Firmware - StorEdge Array A1000/A3x00/A3500FC
Solaris
Release(b)
Solaris
Patches(c)
RM6
Release(d)
RM6
Patches(e)
RDAC
Firmware(f)
2.5.1 FCS
or
2.5.1 4/97
or
2.5.1 8/97
103640-40(kjp)
103622-16(sd)
103934-19(isp)
104312-09(format)
103981-18(glm)
105324-04(ses)
RM6.0 w/
A3000 only
104563-02
104564-03
02.04.1d
RM6.1 w/
A3000 only
105494-01
107995-01(m)
106336-02
02.04.04.01
RM6.1.1u1/u2
w/A1000 or
A3x00
106513-04(n)
106707-05(o)
02.05.06.33
2.5.1 11/97 103640-40(kjp)
103622-16(sd)
103934-19(isp)
104312-09(format)
103981-18(glm)
105324-04(ses)
RM6.1 w/
A3000 only
105494-01
107995-01(m)
106336-02
02.04.04.01
RM6.1.1u1/u2
w/A1000 or
A3x00
106513-04(n)
106707-05(o)
02.05.06.33
RM6.22 108834-07 03.01.03.60
2.6 FCS
or
2.6 3/98
or
2.6 5/98
SCSI 
105181-33(kjp)(i)
105357-04(ses)
105580-19(glm)
106125-13(patch)
106226-03(format)
106655-04(j)
107665-01(k)
RM6.1 w/
A3000 only
105494-01
107995-01(m)
02.04.04.01
RM6.1.1u1/u2
w/A1000 or
A3X00
106513-04(n)
106707-05(o)
02.05.06.33
RM6.22 108834-07 03.01.03.60
RM6.22.1 112125-04 03.01.04.75
Fibre 
105181-33(kjp)(i) 
105356-20(ssd) 
105375-29(sflux) 
106125-13(patch) 
106226-03(format) 
106655-04(j) 
107280-08(ifp) 
107665-01(k)
RM6.22
w/A3500FC,
SOC+ or
FC100
108834-07  
109232-01(nvsram)
109233-01(nvsram)
03.01.03.60 
RM6.22.1
w/A3500FC,
SOC+ or
FC100
112125-04  03.01.04.75 
7 FCS or
7 3/99 or
7 5/99 or
7 8/99 or
7 11/99
SCSI 
106541-23(kjp)
106924-10(isp)
106925-09(glm)
107472-02(l)
RM6.1.1u1/u2
w/A1000 or
A3X00
106513-04(n)
106552-04