-- -- #pragma ident "%Z%%M% %I% %D%" -- -- Fabric Element Management MIB, Version 1.10 (same as version 1.9), as -- per Internet Draft, -- "Definitions of Managed Objects for the Fabric Element in Fibre Channel -- Standard", , July 10, 1998. -- -- This is edited for Brocade implementation. -- (1) The following variables have been changed from read-write to read-only: -- fcFabricName, fcElementName, fcFeModuleName (Config group), -- fcFxPortAdminMode, fcFxPortPhysRttov, fcFxPortBbCreditModel -- (Operational Group). -- (2) The following deprecated objects are not supported: -- FPortFlogiTable { fcFeOp 2 } -- (3) The following textual conventions have been changed slightly: -- MilliSecond and MicroSecond such that the maximum value is -- 2147383647 (2^31 - 1) instead of 4294967295 (2^32 - 1) due to the -- the restriction of the MIB compiler (mibcomp). -- Brocade plans to propose these minor changes to the next version -- of the Internet Draft. -- -- This MIB module is equivalent to femib.smiv2 but it's in SMIv1. -- FCFABRIC-ELEMENT-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, experimental, Counter, Gauge, TimeTicks FROM RFC1155-SMI; fibreChannel OBJECT IDENTIFIER ::= { experimental 42 } -- fcFabric MODULE-IDENTITY -- LAST-UPDATED "9702070000Z" -- ORGANIZATION "ANSI X3T11 Fibre Channel Working Group" -- CONTACT-INFO " Kha Sin Teow -- Brocade Communications Systems, -- 1901 Guadalupe Parkway, -- San Jose, CA 95131 -- U.S.A -- Tel: +1 408 487 8180 -- Fax: +1 408 487 8190 -- Email: khasin@BrocadeComm.COM" -- DESCRIPTION "The MIB module for Fibre Channel Fabric Element." -- REVISION "9710010000Z" -- DESCRIPTION "Version 1.9" -- ::= { fibreChannel 2 } fcFabric OBJECT IDENTIFIER ::= { fibreChannel 2 } -- Fabric Element fcFe OBJECT IDENTIFIER ::= { fcFabric 1 } -- Groups under fcFe fcFeConfig OBJECT IDENTIFIER ::= { fcFe 1 } fcFeOp OBJECT IDENTIFIER ::= { fcFe 2 } fcFeError OBJECT IDENTIFIER ::= { fcFe 3 } fcFeAcct OBJECT IDENTIFIER ::= { fcFe 4 } fcFeCap OBJECT IDENTIFIER ::= { fcFe 5 } -- Type definitions. DisplayString ::= OCTET STRING (SIZE (0..255)) MilliSeconds ::= INTEGER (0..2147383647) -- 2^31 - 1 MicroSeconds ::= INTEGER (0..2147383647) FcNameId ::= OCTET STRING (SIZE (8)) -- Worldwide Name or Fibre Channel Name associated with -- an FC entity. It's a Network_Destination_ID or -- Network_Source_ID composed of a value up to 60 bits -- wide, occupying the remaining 8 bytes while the first -- nibble identifies the format of the Name_Identifier with -- hex values: -- 0: ignored -- 1: IEEE 48-bit address, -- 2: IEEE extended, -- 3: Locally assigned, -- 4: 32-bit IP address FabricName ::= FcNameId -- The Name Identifier of a Fabric. Each Fabric shall -- provide a unique Fabric Name. -- Only the following formats are allowed: IEEE48, and Local. FcPortName ::= FcNameId -- The Name Identifier associated with a port -- Only the following formats are allowed: -- IEEE48, IEEE extended, and Local. FcAddressId ::= OCTET STRING (SIZE (3)) -- Fibre Channel Address Identifier. A 24-bit value unique -- within the address space of a Fabric FcRxDataFieldSize ::= INTEGER (128..2112) -- Receive Data_Field Size FcBbCredit ::= INTEGER (0..32767) -- Buffer-to-buffer Credit -- FC-PH version FcphVersion ::= INTEGER (0..255) -- Class 1 Stacked Connect Support/Mode FcStackedConnMode ::= INTEGER { none (1), transparent (2), lockedDown (3) } -- Class of Service Capability Set FcCosCap ::= INTEGER (0..127) -- bit 0 Class F -- bit 1 Class 1 -- bit 2 Class 2 -- bit 3 Class 3 -- bit 4 Class 4 -- bit 5 Class 5 -- bit 6 Class 6 -- bit 7 reserved for future -- FC-0 Baud Rates Fc0BaudRate ::= INTEGER { other (1), -- none of below oneEighth (2), -- 155 Mbaud (12.5MB/s) quarter (4), -- 266 Mbaud (25.0MB/s) half (8), -- 532 Mbaud (50.0MB/s) full (16), -- 1 Gbaud (100MB/s) double (32), -- 2 Gbaud (200MB/s) quadruple (64) -- 4 Gbaud (400MB/s) } -- Baud Rate Capability Set Fc0BaudRateCap ::= INTEGER (0..127) -- bit 0 other -- bit 1 oneEighth -- bit 2 quarter -- bit 3 half -- bit 4 full -- bit 5 double -- bit 6 quadruple -- bit 7 reserved for future -- FC-0 Media Capability Set Fc0MediaCap ::= INTEGER (0..65535) -- bit 0 unknown -- bit 1 single mode fibre (sm) -- bit 2 multi-mode fibre 50 micron (m5) -- bit 3 multi-mode fibre 62.5 micron (m6) -- bit 4 video cable (tv) -- bit 5 miniature cable (mi) -- bit 6 shielded twisted pair (stp) -- bit 7 twisted wire (tw) -- bit 8 long video (lv) -- bits 9-15 reserved for future use -- A specific FC-0 medium type associated with a port Fc0Medium ::= INTEGER { unknown (1), sm (2), m5 (4), m6 (8), tv (16), mi (32), stp (64), tw (128), lv (256) } -- The FC-0 transmitter type of a port Fc0TxType ::= INTEGER { unknown (1), longWaveLaser (2), -- (LL) shortWaveLaser (3), -- (SL) longWaveLED (4), -- (LE) electrical (5), -- (EL) shortWaveLaser-noOFC (6) -- (SN) } -- The FC-0 distance range associated with a port transmitter Fc0Distance ::= INTEGER { unknown (1), long (2), intermediate (3), short (4) } -- Module and Port Capacity FcFeModuleCapacity ::= INTEGER (1..256) FcFeFxPortCapacity ::= INTEGER (1..256) -- Module, FxPort and NxPort Index FcFeModuleIndex ::= INTEGER (1..256) FcFeFxPortIndex ::= INTEGER (1..256) FcFeNxPortIndex ::= INTEGER (1..126) -- Port Mode FcFxPortMode ::= INTEGER { unknown (1), fPort (2), flPort (3) } -- BB_Credit Model FcBbCreditModel ::= INTEGER { regular (1), alternate (2) } -- The Configuration group -- This group consists of scalar objects and tables. -- It contains the configuration and service parameters -- of the Fabric Element and the FxPorts. -- The group represents a set of parameters associated with -- the Fabric Element or an FxPort to support its NxPorts. -- Implementation of this group is mandatory. fcFabricName OBJECT-TYPE SYNTAX FabricName ACCESS read-only -- instead of read-write STATUS mandatory DESCRIPTION "The Name_Identifier of the Fabric to which this Fabric Element belongs." ::= { fcFeConfig 1 } fcElementName OBJECT-TYPE SYNTAX FcNameId ACCESS read-only -- instead of read-write STATUS mandatory DESCRIPTION "The Name_Identifier of the Fabric Element." ::= { fcFeConfig 2 } fcFeModuleCapacity OBJECT-TYPE SYNTAX FcFeModuleCapacity ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of modules in the Fabric Element, regardless of their current state." ::= { fcFeConfig 3 } -- The Module Table. -- This table contains one entry for each module, -- information of the modules. fcFeModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFeModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each module in the Fabric Element, information of the modules." ::= { fcFeConfig 4 } fcFeModuleEntry OBJECT-TYPE SYNTAX FcFeModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the configuration parameters of a module." INDEX { fcFeModuleIndex } ::= { fcFeModuleTable 1 } FcFeModuleEntry ::= SEQUENCE { fcFeModuleIndex FcFeModuleIndex, fcFeModuleDescr DisplayString, fcFeModuleObjectID OBJECT IDENTIFIER, fcFeModuleOperStatus INTEGER, fcFeModuleLastChange TimeTicks, fcFeModuleFxPortCapacity FcFeFxPortCapacity, fcFeModuleName FcNameId } fcFeModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module within the Fabric Element for which this entry contains information. This value is never greater than fcFeModuleCapacity." ::= { fcFeModuleEntry 1 } fcFeModuleDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A textual description of the module. This value should include the full name and version identification of the module. It should contain printable ASCII characters." ::= { fcFeModuleEntry 2 } fcFeModuleObjectID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The vendor's authoritative identification of the module. This value may be allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides a straight-forward and unambiguous means for determining what kind of module is being managed. For example, this object could take the value 1.3.6.1.4.1.99649.3.9 if vendor 'Neufe Inc.' was assigned the subtree 1.3.6.1.4.1.99649, and had assigned the identifier 1.3.6.1.4.1.99649.3.9 to its 'FeFiFo-16 PlugInCard.'" ::= { fcFeModuleEntry 3 } fcFeModuleOperStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- functional offline (2), -- not available testing (3), -- under testing faulty (4) -- defective } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the operational status of the module: online(1) the module is functioning properly; offline(2) the module is not available; testing(3) the module is under testing; and faulty(4) the module is defective in some way." ::= { fcFeModuleEntry 4 } fcFeModuleLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the value of sysUpTime when the module entered its current operational status. A value of zero indicates that the operational status of the module has not changed since the agent last restarted." ::= { fcFeModuleEntry 5 } fcFeModuleFxPortCapacity OBJECT-TYPE SYNTAX FcFeFxPortCapacity ACCESS read-only STATUS mandatory DESCRIPTION "The number of FxPort that can be contained within the module. Within each module, the ports are uniquely numbered in the range from 1 to fcFeModuleFxPortCapacity inclusive. However, the numbers are not required to be contiguous." ::= { fcFeModuleEntry 6 } fcFeModuleName OBJECT-TYPE SYNTAX FcNameId ACCESS read-only -- instead of read-write STATUS mandatory DESCRIPTION "The Name_Identifier of the module." ::= { fcFeModuleEntry 7 } -- the FxPort Configuration Table. -- This table contains, one entry for each FxPort, -- configuration parameters of the ports. fcFxConfTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxConfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, configuration and service parameters of the FxPorts." ::= { fcFeConfig 5 } fcFxConfEntry OBJECT-TYPE SYNTAX FcFxConfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the configuration and service parameters of a FxPort." INDEX { fcFxConfModuleIndex, fcFxConfFxPortIndex } ::= { fcFxConfTable 1 } FcFxConfEntry ::= SEQUENCE { fcFxConfModuleIndex FcFeModuleIndex, fcFxConfFxPortIndex FcFeFxPortIndex, fcFxPortName FcPortName, -- FxPort common service parameters fcFxPortFcphVersionHigh FcphVersion, fcFxPortFcphVersionLow FcphVersion, fcFxPortBbCredit FcBbCredit, fcFxPortRxBufSize FcRxDataFieldSize, fcFxPortRatov MilliSeconds, fcFxPortEdtov MilliSeconds, -- FxPort class service parameters fcFxPortCosSupported FcCosCap, fcFxPortIntermixSupported INTEGER, fcFxPortStackedConnMode FcStackedConnMode, fcFxPortClass2SeqDeliv INTEGER, fcFxPortClass3SeqDeliv INTEGER, -- other configuration parameters fcFxPortHoldTime MicroSeconds, fcFxPortBaudRate Fc0BaudRate, fcFxPortMedium Fc0Medium, fcFxPortTxType Fc0TxType, fcFxPortDistance Fc0Distance } fcFxConfModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module containing the FxPort for which this entry contains information." ::= { fcFxConfEntry 1 } fcFxConfFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxConfEntry 2 } fcFxPortName OBJECT-TYPE SYNTAX FcPortName ACCESS read-only STATUS mandatory DESCRIPTION "The name identifier of this FxPort. Each FxPort has a unique port name within the address space of the Fabric." ::= { fcFxConfEntry 3 } -- FxPort common service parameters fcFxPortFcphVersionHigh OBJECT-TYPE SYNTAX FcphVersion ACCESS read-only STATUS mandatory DESCRIPTION "The highest or most recent version of FC-PH that the FxPort is configured to support." ::= { fcFxConfEntry 4 } fcFxPortFcphVersionLow OBJECT-TYPE SYNTAX FcphVersion ACCESS read-only STATUS mandatory DESCRIPTION "The lowest or earliest version of FC-PH that the FxPort is configured to support." ::= { fcFxConfEntry 5 } fcFxPortBbCredit OBJECT-TYPE SYNTAX FcBbCredit ACCESS read-only STATUS mandatory DESCRIPTION "The total number of receive buffers available for holding Class 1 connect-request, Class 2 or 3 frames from the attached NxPort. It is for buffer-to-buffer flow control in the direction from the attached NxPort (if applicable) to FxPort." ::= { fcFxConfEntry 6 } fcFxPortRxBufSize OBJECT-TYPE SYNTAX FcRxDataFieldSize ACCESS read-only STATUS mandatory DESCRIPTION "The largest Data_Field Size (in octets) for an FT_1 frame that can be received by the FxPort." ::= { fcFxConfEntry 7 } fcFxPortRatov OBJECT-TYPE SYNTAX MilliSeconds ACCESS read-only STATUS mandatory DESCRIPTION "The Resource_Allocation_Timeout Value configured for the FxPort. This is used as the timeout value for determining when to reuse an NxPort resource such as a Recovery_Qualifier. It represents E_D_TOV (see next object) plus twice the maximum time that a frame may be delayed within the Fabric and still be delivered." ::= { fcFxConfEntry 8 } fcFxPortEdtov OBJECT-TYPE SYNTAX MilliSeconds ACCESS read-only STATUS mandatory DESCRIPTION "The E_D_TOV value configured for the FxPort. The Error_Detect_Timeout Value is used as the timeout value for detecting an error condition." ::= { fcFxConfEntry 9 } -- FxPort class service parameters fcFxPortCosSupported OBJECT-TYPE SYNTAX FcCosCap ACCESS read-only STATUS mandatory DESCRIPTION "A value indicating the set of Classes of Service supported by the FxPort." ::= { fcFxConfEntry 10 } fcFxPortIntermixSupported OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag indicating whether or not the FxPort supports an Intermixed Dedicated Connection." ::= { fcFxConfEntry 11 } fcFxPortStackedConnMode OBJECT-TYPE SYNTAX FcStackedConnMode ACCESS read-only STATUS mandatory DESCRIPTION "A value indicating the mode of Stacked Connect supported by the FxPort." ::= { fcFxConfEntry 12 } fcFxPortClass2SeqDeliv OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag indicating whether or not Class 2 Sequential Delivery is supported by the FxPort." ::= { fcFxConfEntry 13 } fcFxPortClass3SeqDeliv OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag indicating whether or not Class 3 Sequential Delivery is supported by the FxPort." ::= { fcFxConfEntry 14 } -- other FxPort parameters fcFxPortHoldTime OBJECT-TYPE SYNTAX MicroSeconds ACCESS read-only STATUS mandatory DESCRIPTION "The maximum time (in microseconds) that the FxPort shall hold a frame before discarding the frame if it is unable to deliver the frame. The value 0 means that the FxPort does not support this parameter." ::= { fcFxConfEntry 15 } fcFxPortBaudRate OBJECT-TYPE SYNTAX Fc0BaudRate ACCESS read-only STATUS deprecated DESCRIPTION "The FC-0 baud rate of the FxPort." ::= { fcFxConfEntry 16 } fcFxPortMedium OBJECT-TYPE SYNTAX Fc0Medium ACCESS read-only STATUS deprecated DESCRIPTION "The FC-0 medium of the FxPort." ::= { fcFxConfEntry 17 } fcFxPortTxType OBJECT-TYPE SYNTAX Fc0TxType ACCESS read-only STATUS deprecated DESCRIPTION "The FC-0 transmitter type of the FxPort." ::= { fcFxConfEntry 18 } fcFxPortDistance OBJECT-TYPE SYNTAX Fc0Distance ACCESS read-only STATUS deprecated DESCRIPTION "The FC-0 distance range of the FxPort transmitter." ::= { fcFxConfEntry 19 } -- the Operation group -- This group consists of tables that contains operational -- status and established service parameters for the Fabric -- Element and the attached NxPorts. -- Implementation of this group is mandatory. -- The FxPort Operation table -- This table contains, one entry for each FxPort, -- the operational status and parameters of the FxPorts. fcFxPortOperTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, operational status and parameters of the FxPorts." ::= { fcFeOp 1 } fcFxPortOperEntry OBJECT-TYPE SYNTAX FcFxPortOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing operational status and parameters of a FxPort." INDEX { fcFxPortOperModuleIndex, fcFxPortOperFxPortIndex } ::= { fcFxPortOperTable 1 } FcFxPortOperEntry ::= SEQUENCE { fcFxPortOperModuleIndex FcFeModuleIndex, fcFxPortOperFxPortIndex FcFeFxPortIndex, fcFxPortID FcAddressId, fcFPortAttachedPortName FcPortName, fcFPortConnectedPort FcAddressId, fcFxPortBbCreditAvailable Gauge, fcFxPortOperMode FcFxPortMode, fcFxPortAdminMode FcFxPortMode } fcFxPortOperModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module containing the FxPort for which this entry contains information." ::= { fcFxPortOperEntry 1 } fcFxPortOperFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxPortOperEntry 2 } fcFxPortID OBJECT-TYPE SYNTAX FcAddressId ACCESS read-only STATUS mandatory DESCRIPTION "The address identifier by which this FxPort is identified within the Fabric. The FxPort may assign its address identifier to its attached NxPort(s) during Fabric Login." ::= { fcFxPortOperEntry 3 } fcFPortAttachedPortName OBJECT-TYPE SYNTAX FcPortName ACCESS read-only STATUS deprecated DESCRIPTION "The port name of the attached N_Port, if applicable. If the value of this object is '0000000000000000'H, this FxPort has no NxPort attached to it. This variable has been deprecated and may be implemented for backward compability." ::= { fcFxPortOperEntry 4 } fcFPortConnectedPort OBJECT-TYPE SYNTAX FcAddressId ACCESS read-only STATUS deprecated DESCRIPTION "The address identifier of the destination FxPort with which this FxPort is currently engaged in a either a Class 1 or loop connection. If the value of this object is '000000'H, this FxPort is not engaged in a connection. This variable has been deprecated and may be implemented for backward compability." ::= { fcFxPortOperEntry 5 } fcFxPortBbCreditAvailable OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of buffers currently available for receiving frames from the attached port in the buffer-to-buffer flow control. The value should be less than or equal to fcFxPortBbCredit." ::= { fcFxPortOperEntry 6 } fcFxPortOperMode OBJECT-TYPE SYNTAX FcFxPortMode ACCESS read-only STATUS mandatory DESCRIPTION "The current operational mode of the FxPort." ::= { fcFxPortOperEntry 7 } fcFxPortAdminMode OBJECT-TYPE SYNTAX FcFxPortMode ACCESS read-only -- instead of read-write STATUS mandatory DESCRIPTION "The desired operational mode of the FxPort." ::= { fcFxPortOperEntry 8 } -- **************************************************************** -- The F_Port Fabric Login table -- -- This table contains, one entry for each F_Port in the -- Fabric Element, the Service Parameters that have been -- established from the most recent Fabric Login -- (implicit or explicit). -- NOTE WELL: -- This table is deprecated since FEMIB v1.9. -- It is not supported in Silkworm agent after firmware v1.5. -- Instead, the new table, FxPort Fabric Login Table -- (to follow after FxPort Physical Level Table), is supported. -- **************************************************************** -- the FxPort Physical Level table -- This table contains, one entry for each FxPort in the -- Fabric Element, the physical level status and parameters -- of the FxPorts. fcFxPortPhysTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortPhysEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, physical level status and parameters of the FxPorts." ::= { fcFeOp 3 } fcFxPortPhysEntry OBJECT-TYPE SYNTAX FcFxPortPhysEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing physical level status and parameters of a FxPort." INDEX { fcFxPortPhysModuleIndex, fcFxPortPhysFxPortIndex } ::= { fcFxPortPhysTable 1 } FcFxPortPhysEntry ::= SEQUENCE { fcFxPortPhysModuleIndex FcFeModuleIndex, fcFxPortPhysFxPortIndex FcFeFxPortIndex, fcFxPortPhysAdminStatus INTEGER, fcFxPortPhysOperStatus INTEGER, fcFxPortPhysLastChange TimeTicks, fcFxPortPhysRttov MilliSeconds } fcFxPortPhysModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module containing the FxPort for which this entry contains information." ::= { fcFxPortPhysEntry 1 } fcFxPortPhysFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxPortPhysEntry 2 } fcFxPortPhysAdminStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- place port online offline (2), -- take port offline testing (3) -- initiate test procedures } ACCESS read-write STATUS mandatory DESCRIPTION "The desired state of the FxPort. A management station may place the FxPort in a desired state by setting this object accordingly. The testing(3) state indicates that no operational frames can be passed. When a Fabric Element initializes, all FxPorts start with fcFxPortPhysAdminStatus in the offline(2) state. As the result of either explicit management action or per configuration information accessible by the Fabric Element, fcFxPortPhysAdminStatus is then changed to either the online(1) or testing(3) states, or remains in the offline state." ::= { fcFxPortPhysEntry 3 } fcFxPortPhysOperStatus OBJECT-TYPE SYNTAX INTEGER { online (1), -- Login may proceed offline (2), -- Login cannot proceed testing (3), -- port is under test link-failure (4) -- failure after online/testing -- Other values may be used to indicate -- diagnostic for failed test. } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational status of the FxPort. The testing(3) indicates that no operational frames can be passed. If fcFxPortPhysAdminStatus is offline(2) then fcFxPortPhysOperStatus should be offline(2). If fcFxPortPhysAdminStatus is changed to online(1) then fcFxPortPhysOperStatus should change to online(1) if the FxPort is ready to accept Fabric Login request from the attached NxPort; it should proceed and remain in the link-failure(4) state if and only if there is a fault that prevents it from going to the online(1) state." ::= { fcFxPortPhysEntry 4 } fcFxPortPhysLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime at the time the FxPort entered its current operational status. A value of zero indicates that the FxPort's operational status has not changed since the agent last restarted." ::= { fcFxPortPhysEntry 5 } fcFxPortPhysRttov OBJECT-TYPE SYNTAX MilliSeconds ACCESS read-only -- instead of read-write STATUS mandatory DESCRIPTION "The Receiver_Transmitter_Timeout value of the FxPort. This is used by the receiver logic to detect Loss of Synchronization." ::= { fcFxPortPhysEntry 6 } -- The FxPort Fabric Login table -- -- This table contains, one entry for each FxPort in the -- Fabric Element, the Service Parameters that have been -- established from the most recent Fabric Login, -- implicit or explicit. fcFxlogiTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxlogiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, services parameters established from the most recent Fabric Login, explicit or implicit." ::= { fcFeOp 4 } fcFxlogiEntry OBJECT-TYPE SYNTAX FcFxlogiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing service parameters established from a successful Fabric Login." INDEX { fcFxlogiModuleIndex, fcFxlogiFxPortIndex, fcFxlogiNxPortIndex } ::= { fcFxlogiTable 1 } FcFxlogiEntry ::= SEQUENCE { fcFxlogiModuleIndex FcFeModuleIndex, fcFxlogiFxPortIndex FcFeFxPortIndex, fcFxlogiNxPortIndex FcFeNxPortIndex, fcFxPortFcphVersionAgreed FcphVersion, fcFxPortNxPortBbCredit FcBbCredit, fcFxPortNxPortRxDataFieldSize FcRxDataFieldSize, fcFxPortCosSuppAgreed FcCosCap, fcFxPortIntermixSuppAgreed INTEGER, fcFxPortStackedConnModeAgreed FcStackedConnMode, fcFxPortClass2SeqDelivAgreed INTEGER, fcFxPortClass3SeqDelivAgreed INTEGER, -- fcFxPortNxPortName FcPortName, fcFxPortConnectedNxPort FcAddressId, fcFxPortBbCreditModel FcBbCreditModel } fcFxlogiModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module containing the FxPort for which this entry contains information." ::= { fcFxlogiEntry 1 } fcFxlogiFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxlogiEntry 2 } fcFxlogiNxPortIndex OBJECT-TYPE SYNTAX FcFeNxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the associated NxPort in the attachment for which the entry contains information." ::= { fcFxlogiEntry 3 } fcFxPortFcphVersionAgreed OBJECT-TYPE SYNTAX FcphVersion ACCESS read-only STATUS mandatory DESCRIPTION "The version of FC-PH that the FxPort has agreed to support from the Fabric Login" ::= { fcFxlogiEntry 4 } fcFxPortNxPortBbCredit OBJECT-TYPE SYNTAX FcBbCredit ACCESS read-only STATUS mandatory DESCRIPTION "The total number of buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames to be transmitted to the attached NxPort. It is for buffer- to-buffer flow control in the direction from FxPort to NxPort. The buffer-to-buffer flow control mechanism is indicated in the respective fcFxPortBbCreditModel. [1](23.6.2.2)" ::= { fcFxlogiEntry 5 } fcFxPortNxPortRxDataFieldSize OBJECT-TYPE SYNTAX FcRxDataFieldSize ACCESS read-only STATUS mandatory DESCRIPTION "The Receive Data Field Size of the attached NxPort. This is a binary value that specifies the largest Data Field Size for an FT_1 frame that can be received by the NxPort. The value is in number of bytes and ranges from 128 to 2112 inclusive." ::= { fcFxlogiEntry 6 } fcFxPortCosSuppAgreed OBJECT-TYPE SYNTAX FcCosCap ACCESS read-only STATUS mandatory DESCRIPTION "A variable indicating that the attached NxPort has requested the FxPort for the support of classes of services and the FxPort has granted the request." ::= { fcFxlogiEntry 7 } fcFxPortIntermixSuppAgreed OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A variable indicating that the attached NxPort has requested the FxPort for the support of Intermix and the FxPort has granted the request. This flag is only valid if Class 1 service is supported." ::= { fcFxlogiEntry 8 } fcFxPortStackedConnModeAgreed OBJECT-TYPE SYNTAX FcStackedConnMode ACCESS read-only STATUS mandatory DESCRIPTION "A variable indicating whether the FxPort has agreed to support stacked connect from the Fabric Login. This is only meaningful if Class 1 service has been agreed." ::= { fcFxlogiEntry 9 } fcFxPortClass2SeqDelivAgreed OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A variable indicating whether the FxPort has agreed to support Class 2 sequential delivery from the Fabric Login. This is only meaningful if Class 2 service has been agreed." ::= { fcFxlogiEntry 10 } fcFxPortClass3SeqDelivAgreed OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag indicating whether the FxPort has agreed to support Class 3 sequential delivery from the Fabric Login. This is only meaningful if Class 3 service has been agreed." ::= { fcFxlogiEntry 11 } fcFxPortNxPortName OBJECT-TYPE SYNTAX FcPortName ACCESS read-only STATUS mandatory DESCRIPTION "The port name of the attached NxPort, if applicable. If the value of this object is '0000000000000000'H, this FxPort has no NxPort attached to it." ::= { fcFxlogiEntry 12 } fcFxPortConnectedNxPort OBJECT-TYPE SYNTAX FcAddressId ACCESS read-only STATUS mandatory DESCRIPTION "The address identifier of the destination FxPort with which this FxPort is currently engaged in a either a Class 1 or loop connection. If the value of this object is '000000'H, this FxPort is not engaged in a connection." ::= { fcFxlogiEntry 13 } fcFxPortBbCreditModel OBJECT-TYPE SYNTAX FcBbCreditModel ACCESS read-only -- instead of read-write STATUS mandatory DESCRIPTION "This object identifies the BB_Credit model used by the FxPort. The regular model refers to the Buffer-to-Buffer flow control mechanism defined in FC-PH [1] is used between the F_Port and the N_Port. For FL_Ports, the Alternate Buffer-to-Buffer flow control mechanism as defined in FC-AL [4] is used between the FL_Port and any attached NL_Ports." ::= { fcFxlogiEntry 14 } -- the Error group -- This group consists of tables that contain information about -- the various types of errors detected. The management station -- may use the information in this group to determine the -- quality of the link between the FxPort and its attached NxPort. -- Implementation of this group is optional. -- the FxPort Error table -- This table contains, one entry for each FxPort in the Fabric -- Element, counters recording numbers of errors detected -- since the management agent re-initialized. -- The first 6 columnar objects after the port index corresponds -- to the counters in the Link Error Status Block ([1](29.8)). fcFxPortErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each FxPort, counters that record the numbers of errors detected." ::= { fcFeError 1 } fcFxPortErrorEntry OBJECT-TYPE SYNTAX FcFxPortErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing error counters of a FxPort." INDEX { fcFxPortErrorModuleIndex, fcFxPortErrorFxPortIndex } ::= { fcFxPortErrorTable 1 } FcFxPortErrorEntry ::= SEQUENCE { fcFxPortErrorModuleIndex FcFeModuleIndex, fcFxPortErrorFxPortIndex FcFeFxPortIndex, fcFxPortLinkFailures Counter, fcFxPortSyncLosses Counter, fcFxPortSigLosses Counter, fcFxPortPrimSeqProtoErrors Counter, fcFxPortInvalidTxWords Counter, fcFxPortInvalidCrcs Counter, fcFxPortDelimiterErrors Counter, fcFxPortAddressIdErrors Counter, fcFxPortLinkResetIns Counter, fcFxPortLinkResetOuts Counter, fcFxPortOlsIns Counter, fcFxPortOlsOuts Counter } fcFxPortErrorModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module containing the FxPort for which this entry contains information." ::= { fcFxPortErrorEntry 1 } fcFxPortErrorFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxPortErrorEntry 2 } fcFxPortLinkFailures OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of link failures detected by this FxPort." ::= { fcFxPortErrorEntry 3 } fcFxPortSyncLosses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of loss of synchronization detected by the FxPort." ::= { fcFxPortErrorEntry 4 } fcFxPortSigLosses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of loss of signal detected by the FxPort." ::= { fcFxPortErrorEntry 5 } fcFxPortPrimSeqProtoErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of primitive sequence protocol errors detected by the FxPort." ::= { fcFxPortErrorEntry 6 } fcFxPortInvalidTxWords OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of invalid transmission word detected by the FxPort." ::= { fcFxPortErrorEntry 7 } fcFxPortInvalidCrcs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of invalid CRC detected by this FxPort." ::= { fcFxPortErrorEntry 8 } fcFxPortDelimiterErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Delimiter Errors detected by this FxPort." ::= { fcFxPortErrorEntry 9 } fcFxPortAddressIdErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of address identifier errors detected by this FxPort." ::= { fcFxPortErrorEntry 10 } fcFxPortLinkResetIns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Link Reset Protocol received by this FxPort from the attached NxPort." ::= { fcFxPortErrorEntry 11 } fcFxPortLinkResetOuts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Link Reset Protocol issued by this FxPort to the attached NxPort." ::= { fcFxPortErrorEntry 12 } fcFxPortOlsIns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Offline Sequence received by this FxPort." ::= { fcFxPortErrorEntry 13 } fcFxPortOlsOuts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Offline Sequence issued by this FxPort." ::= { fcFxPortErrorEntry 14 } -- Accounting Groups: -- (1) Class 1 Accounting Group, -- (2) Class 2 Accounting Group, and -- (3) Class 3 Accounting Group. -- Each group consists of a table that contains accounting -- information for the FxPorts in the Fabric Element. -- Implementation of each group is optional. -- the Class 1 Accounting table -- This table contains, one entry for each FxPort in the Fabric -- Element, Counters for certain types of events occurred in the -- the FxPorts since the the management agent has re-initialized. -- Implementation of this group is optional. fcFxPortC1AcctTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortC1AcctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, Class 1 accounting information recorded since the management agent has re-initialized." ::= { fcFeAcct 1 } fcFxPortC1AcctEntry OBJECT-TYPE SYNTAX FcFxPortC1AcctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing Class 1 accounting information for each FxPort." INDEX { fcFxPortC1AcctModuleIndex, fcFxPortC1AcctFxPortIndex } ::= { fcFxPortC1AcctTable 1 } FcFxPortC1AcctEntry ::= SEQUENCE { fcFxPortC1AcctModuleIndex FcFeModuleIndex, fcFxPortC1AcctFxPortIndex FcFeFxPortIndex, fcFxPortC1InConnections Counter, fcFxPortC1OutConnections Counter, fcFxPortC1FbsyFrames Counter, fcFxPortC1FrjtFrames Counter, fcFxPortC1ConnTime Counter, fcFxPortC1InFrames Counter, fcFxPortC1OutFrames Counter, fcFxPortC1InOctets Counter, fcFxPortC1OutOctets Counter, fcFxPortC1Discards Counter } fcFxPortC1AcctModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module containing the FxPort for which this entry contains information." ::= { fcFxPortC1AcctEntry 1 } fcFxPortC1AcctFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxPortC1AcctEntry 2 } fcFxPortC1InConnections OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 1 connections successfully established in which the attached NxPort is the source of the connect-request." ::= { fcFxPortC1AcctEntry 3 } fcFxPortC1OutConnections OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 1 connections successfully established in which the attached NxPort is the destination of the connect-request." ::= { fcFxPortC1AcctEntry 4 } fcFxPortC1FbsyFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of F_BSY frames generated by this FxPort against Class 1 connect-request." ::= { fcFxPortC1AcctEntry 5 } fcFxPortC1FrjtFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of F_RJT frames generated by this FxPort against Class 1 connect-request." ::= { fcFxPortC1AcctEntry 6 } fcFxPortC1ConnTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative time that this FxPort has been engaged in Class 1 connection. The amount of time of each connection is counted in octets from after a connect- request has been accepted until the connection is disengaged, either by an EOFdt or Link Reset." ::= { fcFxPortC1AcctEntry 7 } fcFxPortC1InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 1 frames (other than Class 1 connect-request) received by this FxPort from its attached NxPort." ::= { fcFxPortC1AcctEntry 8 } fcFxPortC1OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 1 frames (other than Class 1 connect-request) delivered through this FxPort to its attached NxPort." ::= { fcFxPortC1AcctEntry 9 } fcFxPortC1InOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 1 frame octets, including the frame delimiters, received by this FxPort from its attached NxPort." ::= { fcFxPortC1AcctEntry 10 } fcFxPortC1OutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 1 frame octets, including the frame delimiters, delivered through this FxPort its attached NxPort." ::= { fcFxPortC1AcctEntry 11 } fcFxPortC1Discards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 1 frames discarded by this FxPort." ::= { fcFxPortC1AcctEntry 12 } -- the Class 2 Accounting table -- This table contains, one entry for each FxPort in the Fabric -- Element, Counters for certain types of events occurred in the -- the FxPorts since the the management agent has re-initialized. -- Implementation of this group is optional. fcFxPortC2AcctTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortC2AcctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, Class 2 accounting information recorded since the management agent has re-initialized." ::= { fcFeAcct 2 } fcFxPortC2AcctEntry OBJECT-TYPE SYNTAX FcFxPortC2AcctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing Class 2 accounting information for each FxPort." INDEX { fcFxPortC2AcctModuleIndex, fcFxPortC2AcctFxPortIndex } ::= { fcFxPortC2AcctTable 1 } FcFxPortC2AcctEntry ::= SEQUENCE { fcFxPortC2AcctModuleIndex FcFeModuleIndex, fcFxPortC2AcctFxPortIndex FcFeFxPortIndex, fcFxPortC2InFrames Counter, fcFxPortC2OutFrames Counter, fcFxPortC2InOctets Counter, fcFxPortC2OutOctets Counter, fcFxPortC2Discards Counter, fcFxPortC2FbsyFrames Counter, fcFxPortC2FrjtFrames Counter } fcFxPortC2AcctModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module containing the FxPort for which this entry contains information." ::= { fcFxPortC2AcctEntry 1 } fcFxPortC2AcctFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxPortC2AcctEntry 2 } fcFxPortC2InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 2 frames received by this FxPort from its attached NxPort." ::= { fcFxPortC2AcctEntry 3 } fcFxPortC2OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 2 frames delivered through this FxPort to its attached NxPort." ::= { fcFxPortC2AcctEntry 4 } fcFxPortC2InOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 2 frame octets, including the frame delimiters, received by this FxPort from its attached NxPort." ::= { fcFxPortC2AcctEntry 5 } fcFxPortC2OutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 2 frame octets, including the frame delimiters, delivered through this FxPort to its attached NxPort." ::= { fcFxPortC2AcctEntry 6 } fcFxPortC2Discards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 2 frames discarded by this FxPort." ::= { fcFxPortC2AcctEntry 7 } fcFxPortC2FbsyFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of F_BSY frames generated by this FxPort against Class 2 frames." ::= { fcFxPortC2AcctEntry 8 } fcFxPortC2FrjtFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of F_RJT frames generated by this FxPort against Class 2 frames." ::= { fcFxPortC2AcctEntry 9 } -- the Class 3 Accounting Group -- This table contains, one entry for each FxPort in the Fabric -- Element, Counters for certain types of events occurred in the -- the FxPorts since the management agent has re-initialized. -- Implementation of this group is optional. fcFxPortC3AcctTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortC3AcctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each FxPort in the Fabric Element, Class 3 accounting information recorded since the management agent has re-initialized." ::= { fcFeAcct 3 } fcFxPortC3AcctEntry OBJECT-TYPE SYNTAX FcFxPortC3AcctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing Class 3 accounting information for each FxPort." INDEX { fcFxPortC3AcctModuleIndex, fcFxPortC3AcctFxPortIndex } ::= { fcFxPortC3AcctTable 1 } FcFxPortC3AcctEntry ::= SEQUENCE { fcFxPortC3AcctModuleIndex FcFeModuleIndex, fcFxPortC3AcctFxPortIndex FcFeFxPortIndex, fcFxPortC3InFrames Counter, fcFxPortC3OutFrames Counter, fcFxPortC3InOctets Counter, fcFxPortC3OutOctets Counter, fcFxPortC3Discards Counter } fcFxPortC3AcctModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module containing the FxPort for which this entry contains information." ::= { fcFxPortC3AcctEntry 1 } fcFxPortC3AcctFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxPortC3AcctEntry 2 } fcFxPortC3InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 3 frames received by this FxPort from its attached NxPort." ::= { fcFxPortC3AcctEntry 3 } fcFxPortC3OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 3 frames delivered through this FxPort to its attached NxPort." ::= { fcFxPortC3AcctEntry 4 } fcFxPortC3InOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 3 frame octets, including the frame delimiters, received by this FxPort from its attached NxPort." ::= { fcFxPortC3AcctEntry 5 } fcFxPortC3OutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 3 frame octets, including the frame delimiters, delivered through this FxPort to its attached NxPort." ::= { fcFxPortC3AcctEntry 6 } fcFxPortC3Discards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Class 3 frames discarded by this FxPort." ::= { fcFxPortC3AcctEntry 7 } -- The Capability Group - consists of a table describing -- information about what each FxPort is inherently capable -- of operating or supporting. -- A capability may be used, as expressed in its respective -- object value in the Configuration group. -- Implementation of this group is optional. fcFxPortCapTable OBJECT-TYPE SYNTAX SEQUENCE OF FcFxPortCapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each FxPort, the capabilities of the port within the Fabric Element." ::= { fcFeCap 1 } fcFxPortCapEntry OBJECT-TYPE SYNTAX FcFxPortCapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the capabilities of a FxPort." INDEX { fcFxPortCapModuleIndex, fcFxPortCapFxPortIndex } ::= { fcFxPortCapTable 1 } FcFxPortCapEntry ::= SEQUENCE { fcFxPortCapModuleIndex FcFeModuleIndex, fcFxPortCapFxPortIndex FcFeFxPortIndex, fcFxPortCapFcphVersionHigh FcphVersion, fcFxPortCapFcphVersionLow FcphVersion, fcFxPortCapBbCreditMax FcBbCredit, fcFxPortCapBbCreditMin FcBbCredit, fcFxPortCapRxDataFieldSizeMax FcRxDataFieldSize, fcFxPortCapRxDataFieldSizeMin FcRxDataFieldSize, fcFxPortCapCos FcCosCap, fcFxPortCapIntermix INTEGER, fcFxPortCapStackedConnMode FcStackedConnMode, fcFxPortCapClass2SeqDeliv INTEGER, fcFxPortCapClass3SeqDeliv INTEGER, fcFxPortCapHoldTimeMax MicroSeconds, fcFxPortCapHoldTimeMin MicroSeconds, fcFxPortCapBaudRates Fc0BaudRateCap, fcFxPortCapMedia Fc0MediaCap } fcFxPortCapModuleIndex OBJECT-TYPE SYNTAX FcFeModuleIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the module containing the FxPort for which this entry contains information." ::= { fcFxPortCapEntry 1 } fcFxPortCapFxPortIndex OBJECT-TYPE SYNTAX FcFeFxPortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the FxPort within the module. This number ranges from 1 to the value of fcFeModulePortCapacity for the associated module. The value remains constant for the identified FxPort until the module is re-initialized." ::= { fcFxPortCapEntry 2 } fcFxPortCapFcphVersionHigh OBJECT-TYPE SYNTAX FcphVersion ACCESS read-only STATUS mandatory DESCRIPTION "The highest or most recent version of FC-PH that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 3 } fcFxPortCapFcphVersionLow OBJECT-TYPE SYNTAX FcphVersion ACCESS read-only STATUS mandatory DESCRIPTION "The lowest or earliest version of FC-PH that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 4 } fcFxPortCapBbCreditMax OBJECT-TYPE SYNTAX FcBbCredit ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of receive buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames from the attached NxPort." ::= { fcFxPortCapEntry 5 } fcFxPortCapBbCreditMin OBJECT-TYPE SYNTAX FcBbCredit ACCESS read-only STATUS mandatory DESCRIPTION "The minimum number of receive buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames from the attached NxPort." ::= { fcFxPortCapEntry 6 } fcFxPortCapRxDataFieldSizeMax OBJECT-TYPE SYNTAX FcRxDataFieldSize ACCESS read-only STATUS mandatory DESCRIPTION "The maximum size in bytes of the Data Field in a frame that the FxPort is capable of receiving from its attached NxPort." ::= { fcFxPortCapEntry 7 } fcFxPortCapRxDataFieldSizeMin OBJECT-TYPE SYNTAX FcRxDataFieldSize ACCESS read-only STATUS mandatory DESCRIPTION "The minimum size in bytes of the Data Field in a frame that the FxPort is capable of receiving from its attached NxPort." ::= { fcFxPortCapEntry 8 } fcFxPortCapCos OBJECT-TYPE SYNTAX FcCosCap ACCESS read-only STATUS mandatory DESCRIPTION "A value indicating the set of Classes of Service that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 9 } fcFxPortCapIntermix OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag indicating whether or not the FxPort is capable of supporting the intermixing of Class 2 and Class 3 frames during a Class 1 connection. This flag is only valid if the port is capable of supporting Class 1 service." ::= { fcFxPortCapEntry 10 } fcFxPortCapStackedConnMode OBJECT-TYPE SYNTAX FcStackedConnMode ACCESS read-only STATUS mandatory DESCRIPTION "A value indicating the mode of Stacked Connect request that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 11 } fcFxPortCapClass2SeqDeliv OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag indicating whether or not the FxPort is capable of supporting Class 2 Sequential Delivery." ::= { fcFxPortCapEntry 12 } fcFxPortCapClass3SeqDeliv OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag indicating whether or not the FxPort is capable of supporting Class 3 Sequential Delivery." ::= { fcFxPortCapEntry 13 } fcFxPortCapHoldTimeMax OBJECT-TYPE SYNTAX MicroSeconds ACCESS read-only STATUS mandatory DESCRIPTION "The maximum holding time (in microseconds) that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 14 } fcFxPortCapHoldTimeMin OBJECT-TYPE SYNTAX MicroSeconds ACCESS read-only STATUS mandatory DESCRIPTION "The minimum holding time (in microseconds) that the FxPort is capable of supporting." ::= { fcFxPortCapEntry 15 } fcFxPortCapBaudRates OBJECT-TYPE SYNTAX Fc0BaudRateCap ACCESS read-only STATUS deprecated DESCRIPTION "A value indicating the set of baud rates that the FxPort is capable of supporting. This variable has been deprecated and may be implemented for backward compability." ::= { fcFxPortCapEntry 16 } fcFxPortCapMedia OBJECT-TYPE SYNTAX Fc0MediaCap ACCESS read-only STATUS deprecated DESCRIPTION "A value indicating the set of media that the FxPort is capable of supporting. This variable has been deprecated and may be implemented for backward compability." ::= { fcFxPortCapEntry 17 } END