AQ_TM_PROCESSES

Property Description
Parameter type Integer
Default value 0
Modifiable ALTER SYSTEM
Range of values 0 to 10
Basic No

AQ_TM_PROCESSES enables time monitoring of queue messages. The times can be used in messages that specify delay and expiration properties. Values from 1 to 10 specify the number of queue monitor processes created to monitor the messages. If AQ_TM_PROCESSES is not specified or is set to 0, then the queue monitor is not created.