showenvironment


Use the showenvironment command to display a snapshot of the server's environmental status. The information this command can display includes system temperatures, hard disk drive status, power supply and fan status, front panel LED status, keyswitch position, voltage and current sensors, and so on. The output uses a format similar to the UNIX command prtdiag(1m).

How to Use the showenvironment Command

Note: You do not need user permissions to use this command.

At the sc> prompt, type the following command:

sc> showenvironment

The display output differs according to your host server's model and configuration. Some environmental information might not be available when the server is in standby mode.

For example:

sc> showenvironment

=============== Environmental Status ===============

--------------------------------------------------------------------------------
System Temperatures (Temperatures in Celsius):
--------------------------------------------------------------------------------

Sensor Status Temp LowHard LowSoft LowWarn HighWarn HighSoft HighHard

--------------------------------------------------------------------------------

C0.P0.T_CORE OK 48 -20 -10 0 97 102 120
C1.P0.T_CORE OK 53 -20 -10 0 97 102 120
C2.P0.T_CORE OK 49 -20 -10 0 97 102 120
C3.P0.T_CORE OK 57 -20 -10 0 97 102 120
C0.T_AMB OK 28 -20 -10 0 70 82 87
C1.T_AMB OK 33 -20 -10 0 70 82 87
C2.T_AMB OK 27 -20 -10 0 70 82 87
C3.T_AMB OK 28 -20 -10 0 70 82 87
MB.T_AMB OK 32 -18 -10 0 65 75 87

--------------------------------------
Front Status Panel:
--------------------------------------
Keyswitch position: NORMAL


---------------------------------------------------
System Indicator Status:
---------------------------------------------------
SYS.LOCATE SYS.SERVICE SYS.ACT
--------------------------------------------------------
OFF OFF ON


--------------------------------------------
System Disks:
--------------------------------------------

Disk Status Service OK2RM
------ ------ ------- -----
HDD0 OK OFF OFF
HDD1 OK OFF OFF
HDD2 OK OFF OFF
HDD3 OK OFF OFF


----------------------------------------------------------
Fans (Speeds Revolution Per Minute):
----------------------------------------------------------

Sensor Status Speed Warn Low
------------ ---------- ---------- ---------- -------
FT0.F0.TACH OK 3879 2400 750
FT1.F0.TACH OK 3947 2400 750
FT2.F0.TACH OK 4017 2400 750
FT3.F0 OK -- -- --


--------------------------------------------------------------------------------
Voltage sensors (in Volts):
--------------------------------------------------------------------------------

Sensor Status Voltage LowSoft LowWarn HighWarn HighSoft
--------------- ------ ------- -------- -------- --------- ---------
MB.V_+1V5 OK 1.49 1.20 1.27 1.72 1.80
MB.V_VCCTM OK 2.53 2.00 2.12 2.87 3.00
MB.V_NET0_1V2D OK 1.26 0.96 1.02 1.38 1.44
MB.V_NET1_1V2D OK 1.26 0.96 1.02 1.38 1.44
MB.V_NET0_1V2A OK 1.26 0.96 1.02 1.38 1.44
MB.V_NET1_1V2A OK 1.25 0.96 1.02 1.38 1.44
MB.V_+3V3 OK 3.38 2.64 2.80 3.79 3.96
MB.V_+3V3STBY OK 3.33 2.64 2.80 3.79 3.96
MB.BAT.V_BAT OK 3.07 -- 2.25 -- --
MB.V_SCSI_CORE OK 1.80 1.44 1.53 2.07 2.16
MB.V_+5V OK 5.02 4.00 4.25 5.75 6.00
MB.V_+12V OK 12.00 9.60 10.20 13.80 14.40
MB.V_-12V OK -11.96 -14.40 -13.80 -10.20 -9.60


-------------------------------------------------
Power Supply Indicators:
-------------------------------------------------

Supply ACTIVE Service OK-to-Remove
-------- ----- ---------- ----------------
PS0 ON OFF OFF
PS1 ON OFF OFF
PS2 ON OFF OFF
PS3 ON OFF OFF


---------------------
Power Supplies:
---------------------

Supply Supply Supply Supply Supply Supply Status
------- ------- ------- ------- ------- ------- -----
PS0 ON OFF OFF OFF OFF OFF
PS1 ON OFF OFF OFF OFF OFF
PS2 ON OFF OFF OFF OFF OFF
PS3 ON OFF OFF OFF OFF OFF

----------------------
Current sensors:
----------------------

Sensor Status
------------- -----------
MB.FF_SCSIA OK
MB.FF_SCSIB OK
MB.FF_POK OK
C0.P0.FF_POK OK
C1.P0.FF_POK OK
C2.P0.FF_POK OK
C3.P0.FF_POK OK

----------------------
System Alarms:
----------------------

Alarm Relay LED
----------------- ----- -----
ALARM.CRITICAL OFF OFF
ALARM.MAJOR OFF OFF
ALARM.MINOR OFF OFF
ALARM.USER OFF OFF


The following example shows the environmental information you might see when the host server is powered off.

---------------------------------------------------------------------------------------------------
System Temperatures (Temperatures in Celsius):
---------------------------------------------------------------------------------------------------

Sensor Status Temp LowHard LowSoft LowWarn HighWarn HighSoft HighHard

CPU temperature information cannot be displayed when System power is off

----------------------------------------------------------------------------------------------------------------
MB.T_AMB OK 22 -11 -9 -7 57 60 63

--------------------------------------
Front Status Panel:
--------------------------------------
Keyswitch position: UNKNOWN
--------------------------------------------------------
System Indicator Status:
--------------------------------------------------------

SYS.LOCATE SYS.SERVICE SYS.ACT
------- ------- -------
OFF OFF OFF

Disk Status information cannot be displayed when System power is off.
Fan Status information cannot be displayed when System power is off.
Voltage Rail Status information cannot be displayed when System power is off.

--------------------------------------------
Power Supply Indicators:
--------------------------------------------

Supply Active Service OK-to-Remove
------- ------- ------- -------
PS0 ON OFF OFF
PS1 ON OFF OFF

Supply Active Service OK-to-Remove
--------------------------------------------
PS0 ON OFF OFF
PS1 ON OFF OFF

---------------------------------------------------------------------------------------------------


ALOM shell commands

Types of ALOM commands