Sun StorEdge 3000 Family FRU Installation Guide
|
    |
Sun StorEdge 3000 Family FRUs
|
This document provides instructions for removing and installing field-replaceable units (FRUs) in Sun StorEdge
3120 SCSI arrays, Sun StorEdge 3310 SCSI arrays, and Sun StorEdge 3510 FC arrays.
Instructions are also included for FRUs which are common to all three arrays. These FRU components can be replaced by customers or by Sun service representatives.
This chapter covers the following topics:
Removal and installation instructions are provided for the following FRUs:
- Disk drives
- Power and fan modules
- Card modules
- Special-Use FRUs, such as batteries
1.1 Available FRUs
Most FRUs are hot-swappable except a few modules which are hot-serviceable. Hot-serviceable means that the module can be replaced while the RAID product and hosts are powered up but the connected hosts must be inactive.
|
Caution - Please follow the FRU procedures carefully to ensure successful FRU replacement.
|
The following tables list the FRUs that are currently available. For additional FRUs and X-options, consult your sales representative or the latest Release Notes for Sun StorEdge 3000 Family products on Sun web sites.
TABLE 1-1 List of Available FRUs for the Sun StorEdge 3120 SCSI Array
FRU Model Number
|
Description
|
F370-6195-xx
|
1U JBOD, LVD, Chassis + I/O board with SAF-TE
|
F370-6193-xx
|
AC power supply and fan module, 1U
|
F370-6192-xx
|
DC power supply and fan module, 1U
|
F370-5405-xx
|
Cable, LVD, 1-foot, jumper
|
F370-5528-xx
|
Cable, LVD, 1.5-foot, expansion
|
F540-6054-xx
|
Drive module, 36 GB LVD, 10K RPM
|
F540-6055-xx
|
Drive module, 36 GB LVD, 15K RPM
|
F540-6056-xx
|
Drive module, 73 GB LVD, 10K RPM
|
F540-6057-xx
|
Drive module, 73 GB LVD, 15K RPM
|
F540-6058-xx
|
Drive module, 146 GB LVD, 10K RPM
|
XTA-3000-AMBS
|
Air management blank sled
|
|
Caution - You can mix capacity in the same chassis, but not spindle speed (RPMs) on the same SCSI bus. For instance, you can use 36 Gbyte and 73 Gbyte drives with no performance problems if both are 10K RPM drives. Violating this configuration guideline leads to poor performance.
|
TABLE 1-2 List of Available FRUs for the Sun StorEdge 3310 SCSI Array
FRU Model Number
|
Description
|
F370-5394-xx
|
Event monitoring unit
|
F370-5396-xx
|
I/O module, LVD, expansion unit or JBOD
|
F370-5397-xx
|
I/O module, LVD, RAID
|
F370-5403-xx
|
Controller module, 512 memory, battery, 2U LVD
|
F370-5399-xx
|
Terminator module
|
F540-5522-xx
|
Drive module, 36GB LVD, 10K RPM
|
F540-5563-xx
|
Drive module, 73GB LVD, 10K RPM
|
F370-5398xxAC
|
AC power and fan module, 2U
|
F370-5527-xxDC
|
DC power and fan module, 2U
|
F370-5533-xx
|
Battery, LVD
|
F370-5405-xx
|
Cable, LVD, 1-foot, jumper
|
F370-5528-xx
|
Cable, LVD, 1.5-foot, expansion
|
F370-5393-xx
|
Box, 2U, JBOD, LVD
|
F370-5524-xx
|
Box, 2U, RAID, LVD
|
XTA-3310-DC-KIT
|
Power and fan module, 2U, DC
|
TABLE 1-3 List of Available FRUs for the Sun StorEdge 3510 FC Array
FRU Model Number
|
Description
|
F370-5535-xx
|
Box, 2U, FC, Chassis + Backplane (RAID/JBOD)
|
F370-5545-xx
|
Battery, FC, 2U
|
F370-5540-xx
|
Cable, FC, 1.5 FT, expansion
|
F370-5537-xx
|
I/O w/SES and RAID Controller FC, 1GB memory, battery, 2U
|
F370-5538-xx
|
I/O w/SES, JBOD FC, 2U
|
F370-5398-xx
|
AC power supply/fan module, 2U
|
XTA-3310-DC-Kit
|
DC power supply/fan module, 2U
|
XTA-3510-36GB-15K
|
Drive module, 36GB FC, 15KRPM
|
XTA-3510-73GB-10K
|
Drive module, 73GB FC, 10KRPM
|
XTA-3510-146GB-10K
|
Drive module, 146GB FC, 10KRPM
|
XTA-3000-AMBS
|
Air Management Sled
|
XSFP-SW-2GB
|
SFP, 2G, SW 850NM, FC, TRANS
|
XSFP-LW-2GB
|
SFP, 2G, LW 1310NM, FC, TRANS
|
1.2 Static Electricity Precautions
Follow these steps to prevent damaging the FRUs:
- Remove plastic, vinyl, and foam from the work area.
- Before handling a FRU, discharge any static electricity by touching a ground surface.
- Wear an antistatic wrist strip.
- Do not remove a FRU from its antistatic protective bag until you are ready to install it.
- When removing a FRU from the RAID product, immediately place it in an antistatic bag and in antistatic packaging.
- Handle a FRU only by its edges, and avoid touching the circuitry.
- Do not slide a FRU over any surface.
- Limit body movement (which builds up static electricity) during FRU installation.
Sun StorEdge 3000 Family FRU Installation Guide
|
816-7326-16
|
    |
Copyright © 2004, Sun Microsystems, Inc. All rights reserved.